"end of interval" in SMF.

How to do Performance analysis and Capacity Planning for a shop. We also talk about Software Cost here.
Previous topicNext topic

Topic Author
Prakash Jha
Registered Member
Posts: 43
Joined: Sat Jun 29, 2013 1:45 pm
Zodiac: Sagittarius

"end of interval" in SMF.

Post by Prakash Jha » Mon Mar 27, 2017 3:09 pm

Hi,

I have been reading about SMF records for knowledge and stuck on a phrase which seems to be used at many places in the docment and the phrase is, "end of interval". What exactly "end of interval" means, can someone please guide me on this? For example, it's written like, SMF 30 and subtype 2 & SMF 30 and subtype 3 are written at end of interval ... :?



User avatar

Robert Sample
Global Moderator
Global Moderator
Posts: 1340
Joined: Fri Jun 28, 2013 1:22 am
Location: Dubuque Iowa
Zodiac: Virgo

Re: "end of interval" in SMF.

Post by Robert Sample » Mon Mar 27, 2017 4:06 pm

In the SMFPRMxx member of SYS1.PARMLIB, the system programmer specifies the interval time (usually one of 15 minutes, 30 minutes, or 60 minutes -- the default is 30 although any value evenly divisible into 60 works) as well as the sync time (default is 00) which indicates when the interval ends (00 to 59). If an address space is executing when the interval end occurs, an SMF type 30 subtype 2 or 3 record will be generated.